Why do meters reject fresh DLMS connections after TCP keep-alive disconnects with frame-counter-out-of-sequence?

Scheduled Pinned Locked Moved General Discussion
dlmscoseminvocation-counanti-replaysecurity-suite
10 Posts 6 Posters 43 Views 1 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
  • M Offline
    M Offline
    marcus_vance
    wrote on last edited by
    #1

    [!WARNING]
    Technical Redaction & Safe Harbor Notice:
    All communication captures, system titles, and cryptographic parameters in this thread have been sanitized and neutralized. Real utility meter identifiers, production encryption keys (GUEK/GAK/MK), SIM IMSIs, and proprietary network envelopes have been substituted with standard IEC 62056 synthetic test vectors. Do not post unredacted production captures or live cryptographic keys.

    We are managing a fleet of 50,000 smart meters communicating over cellular NB-IoT to a centralized Head-End System (HES). When an active TCP connection drops due to cellular network tower handovers or keep-alive timeouts, the meter reconnects to HES and establishes a fresh TCP socket on port 4059.

    Upon reconnecting, HES sends an initial AARQ followed by an encrypted Get-Request using Security Suite 1 (0xDB General-Glo-Ciphering).
    However, the meter immediately drops the frame or returns action-response-with-service-error: frame-counter-out-of-sequence!

    Our HES server maintains a stateful database, but whenever a worker thread restarts, it re-initializes the Invocation Counter ($IC$) to 1. Why does the meter permanently reject connections after socket restarts?

    1 Reply Last reply
    0
    • A Offline
      A Offline
      alex_turner
      wrote on last edited by
      #2

      Marcus, this is the core security invariant of DLMS Security Suite 1: The Invocation Counter ($IC$) is persistent across connection lifetimes.

      Per DLMS Green Book 10th Ed Section 9.2.5.3 (Invocation Counter Management) and IEC 62056-53 Section 8.4.2:
      The 4-byte Invocation Counter ($IC$) is a strictly monotonic anti-replay sequence number.

      The Meter's Non-Volatile Persistence:

      In the meter's security engine (Class 64 Security Setup), the meter stores the last verified Invocation Counter from Client SAP 0x0001 in non-volatile memory (EEPROM / Flash):
      $$\text{Condition: } IC_{\text{rx}} > IC_{\text{persisted}}$$

      If your HES worker thread restarts and resets $IC$ to 1 (or any value $\le IC_{\text{persisted}}$), the meter's AES-GCM decryption engine flags an active replay attack and drops the frame by design!

      1 Reply Last reply
      0
      • D Offline
        D Offline
        david_miller
        wrote on last edited by
        #3

        How should HES synchronize its Invocation Counter when state is lost?

        Per DLMS Blue Book Ed. 17 Section 4.6.2 (Security Setup Class 64):
        Class 64 defines Attribute 4: global_invocation_counter (Double-Long-Unsigned).

        The Standard Synchronization Handshake:

        1. Connect via Public Client (Client SAP 0x0010):
          Public Client requires no encryption and allows reading Public objects;
        2. Read Current Meter IC:
          Issue Get-Request-Normal for OBIS 0.0.43.1.0.255 (or associated Security Setup object) Attribute 4;
        3. Synchronize HES Counter:
          $$\text{HES } IC = \text{Meter } IC + 100$$ (advance by a safety margin);
        4. Connect via Management Client (Client SAP 0x0001):
          Transmit AARQ and ciphered APDUs using the newly synchronized $IC$.
        1 Reply Last reply
        0
        • E Offline
          E Offline
          elena_rostova
          wrote on last edited by
          #4

          From the firmware implementation side, we write the latest $IC$ to Flash every $N$ transactions (and cache in battery-backed RAM) with an anti-wear leveling algorithm.

          When the meter powers on or re-establishes an association, it loads $IC_{\text{persisted}}$. If a client attempts a brute-force connection with lower $IC$, the meter will lock out the association after 3 failed attempts per Class 65 (Single Port Protection).

          1 Reply Last reply
          0
          • S Offline
            S Offline
            sarah_jenkins
            wrote on last edited by
            #5

            Let's look at the OBIS code for the Invocation Counter across different Security Setup instances:

            • Management Security Setup (Client SAP 1): 0.0.43.1.0.255
            • Firmware Upgrade Security Setup (Client SAP 2): 0.0.43.1.1.255
            • Customer Gateway Security Setup (Client SAP 3): 0.0.43.1.2.255

            Each logical client has an independent, non-overlapping Invocation Counter tracking sequence!

            1 Reply Last reply
            0
            • C Offline
              C Offline
              carlos_mendez
              wrote on last edited by
              #6

              We tested the Public Client pre-read in the field across 200 failing meters:
              In every single case, reading Attribute 4 of 0.0.43.1.0.255 showed the meter was at $IC = 14{,}280$, while our restarted HES was trying to send $IC = 1$.
              Once we synced HES to $14{,}300$, all 200 meters reconnected instantly without a single drop!

              1 Reply Last reply
              0
              • M Offline
                M Offline
                marcus_vance
                wrote on last edited by
                #7

                Here is the verified Public Client read request for the Invocation Counter:

                00 01 00 10 00 01 00 0D C0 01 C1 00 40 00 00 2B 01 00 FF 04 00
                
                • Client SAP: 0x0010 (Public Client 16)
                • Class ID: 0x0040 (Class 64 Security Setup)
                • OBIS: 0.0.43.1.0.255
                • Attribute: 4 (global_invocation_counter)

                And the meter's response returning current $IC = 14{,}280$ (0x000037C8😞

                00 01 00 10 00 01 00 09 C4 01 C1 00 06 00 00 37 C8
                
                1 Reply Last reply
                0
                • A Offline
                  A Offline
                  alex_turner
                  wrote on last edited by
                  #8

                  Notice how the Public Client read solves the cold-start problem cleanly without exposing any secret keys!

                  1 Reply Last reply
                  0
                  • E Offline
                    E Offline
                    elena_rostova
                    wrote on last edited by
                    #9

                    Always ensure that your HES advances the counter by a small margin (+10 to +100) before transmitting the first ciphered APDU to absorb any unacknowledged frames in transit.

                    1 Reply Last reply
                    0
                    • M Offline
                      M Offline
                      marcus_vance
                      wrote on last edited by
                      #10

                      To synthesize for the community, here is the complete Python Gurux script demonstrating automated $IC$ synchronization:

                      from gurux_dlms.objects import GXDLMSSecuritySetup
                      from gurux_dlms.enums import Security, Authentication
                      
                      def synchronize_invocation_counter(reader, client, security_obis="0.0.43.1.0.255"):
                          # 1. Connect temporarily as Public Client (SAP 16)
                          client.clientAddress = 16
                          client.authentication = Authentication.NONE
                          client.ciphering.security = Security.NONE
                          
                          # 2. Read Global Invocation Counter (Class 64, Attribute 4)
                          ss = GXDLMSSecuritySetup(security_obis)
                          current_ic = reader.read(ss, 4)
                          print(f"[+] Current Meter Persisted Invocation Counter: {current_ic}")
                          
                          # 3. Synchronize Management Client with Safety Advance (+50)
                          client.clientAddress = 1 # Management Client SAP 1
                          client.authentication = Authentication.HIGH_GMAC
                          client.ciphering.security = Security.AUTHENTICATION_ENCRYPTION
                          client.ciphering.invocation_counter = current_ic + 50
                          
                          print(f"[+] Management Client IC synchronized to {client.ciphering.invocation_counter}. Ready for AARQ.")
                      

                      Summary Checklist:

                      1. $IC$ Persistence: Invocation Counters survive reboots and socket disconnects (Green Book Section 9.2.5.3).
                      2. Cold-Start Sync: Read Attribute 4 of Class 64 via Public Client (SAP 16).
                      3. Safety Advance: Set $IC = IC_{\text{meter}} + 50$ to avoid race conditions.
                      1 Reply Last reply
                      0

                      Hello! It looks like you're interested in this conversation, but you don't have an account yet.

                      Getting fed up of having to scroll through the same posts each visit? When you register for an account, you'll always come back to exactly where you were before, and choose to be notified of new replies (either via email, or push notification). You'll also be able to save bookmarks and upvote posts to show your appreciation to other community members.

                      With your input, this post could be even better 💗

                      Register Login
                      Reply