DLMS/COSEM Activity Calendar (Class 20) TOU Tariff Table Switching

Scheduled Pinned Locked Moved General Discussion
activity-calendtoutariffclass-20smart-grid
3 Posts 3 Posters 19 Views 1 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
  • S Offline
    S Offline
    sarah_jenkins
    wrote on last edited by
    #1

    Managing Time-of-Use (TOU) Rates via Class 20

    Configuring complex Time-of-Use (Peak, Off-Peak, Shoulder) electricity billing in DLMS meters relies on Class 20 (Activity Calendar).

    Key Attributes

    • OBIS Code: 0.0.13.0.0.255 (Activity Calendar 1)
    • Attribute 2 (calendar_name_active): Currently running tariff schedule name
    • Attribute 3 (season_profile_active): Active seasonal date transitions
    • Attribute 4 (week_profile_table_active): Active Monday-Sunday day profile mappings
    • Attribute 5 (day_profile_table_active): Hourly tariff switching schedule
    • Attribute 6-9 (*_passive): Staged schedule for future activation
    • Attribute 10 (activate_passive_calendar_time): Execution timestamp

    Two-Step Safe Activation Pattern

    1. Write new season, week, and day profiles into the Passive attributes (Attributes 6, 7, 8).
    2. Set activate_passive_calendar_time (Attribute 10) to the scheduled rollout datetime (e.g., 2026-10-01 00:00:00) or execute activate_passive_calendar (Method 1) for immediate activation.
    1 Reply Last reply
    0
    • M Offline
      M Offline
      marcus_vance
      wrote on last edited by
      #2

      Staging through passive attributes is mandatory for utility compliance. It allows verifying the complete tariff table on millions of meters weeks in advance without affecting real-time billing before the fiscal date.

      1 Reply Last reply
      0
      • E Offline
        E Offline
        elena_rostova
        wrote on last edited by
        #3

        Meter firmware tip: When writing day_profile_table_passive, ensure script selectors match the IDs in the Script Table (0.0.10.0.100.255) for tariff register switching. If a script ID is invalid, the meter returns object-undefined on write.

        1 Reply Last reply
        0

        Hello! It looks like you're interested in this conversation, but you don't have an account yet.

        Getting fed up of having to scroll through the same posts each visit? When you register for an account, you'll always come back to exactly where you were before, and choose to be notified of new replies (either via email, or push notification). You'll also be able to save bookmarks and upvote posts to show your appreciation to other community members.

        With your input, this post could be even better 💗

        Register Login
        Reply
        • Reply as topic
        Log in to reply
        • Oldest to Newest
        • Newest to Oldest
        • Most Votes


        • Login

        • Don't have an account? Register

        • Login or register to search.
        Powered by NodeBB Contributors
        • First post
          Last post
        0
        • Categories
        • Recent
        • Tags
        • Popular
        • World
        • Users
        • Groups